Build Over Agreements for Home Improvements
Build over agreements
A build over agreement is a contract between you and your sewage provider, when you’re building over, or near a sewer. It’s in place to protect the sewers and drains supplying you, and your neighbours. The agreement also makes sure Thames Water has access to maintain or repair the sewer network.
You shouldn’t start construction work before getting an agreement. We might need to make changes to your design, which could cause you additional costs or delays. Planning permission does not grant you permission to build over a sewer or drain.
When you need a build over agreement
Sewers often run beneath back gardens, particularly in urban areas. It’s likely that you’ll need to make an application if you’re building within 3 metres of a public sewer, or within 1 metre of a public lateral drain.
If you’re building a new property, you must apply to have the sewer diverted rather than a build over agreement (including new car ports or sheds that are not attached to your property).
Liability for any damage caused to the sewers or drains during the construction lies with you.
Finding sewers or drains
Your builder or a drainage specialist can conduct a survey to identify location and size of sewers or drains within your property boundary.
If you’d like to review maps detailing our infrastructure and assets, you can view these free of charge by appointment.
To book an appointment, please email us.
The terminal is located at:
Thames Water Clearwater Court, Vastern Road, Reading, RG1 8DB
Online sewer maps are also available to purchase from all utility searches companies, or from our Property Searches department.
If your sewers aren’t mapped, this video will help your builder identify sewers in your property boundary.
Apply for a build over agreement
If you know you need a build over agreement, you can apply online.
If you’re unsure, please use our online service to tell us about your plans, and we’ll advise if you need to complete a build over agreement.
The difference between public and private sewers
Thames Water is responsible for all public sewers and lateral drains in our region. Private drains are the responsibility of the landowner.
You’ll need to apply for a build over agreement if you’re building:
- Within 3 metres of a public sewer
- Within 1 metre of the point where a pipe serving only your property crosses your boundary (where it becomes a public lateral drain)
This diagram shows the difference between public and private drains and public sewers.
Why is it important to get a build over agreement?
Thames Water is responsible for all public sewers and public lateral drains in our region. We need to be certain your building work doesn’t restrict our ability to maintain and repair these pipes. And we also need to make sure the extra weight of your new building doesn’t damage the pipe.
Without a build over agreement, you may not be granted a Building Regulations completion certificate, which may cause you problems when selling your property. Planning permission may also be required from the local planning authority.
We have legal powers under the Water Industry Act 1991, giving us the right to maintain, repair, replace and renew public sewers. If any building work limits this, we could seek an injunction to remove the building and potentially recover damages.
When can’t I build over a sewer?
Manholes
If there’s a manhole in the area you intend to build on, you’ll need to relocate it. Internal manholes aren’t permitted, to protect your property from odours and an increased risk of flooding. You must complete the build over application form to relocate a manhole.
Strategic sewers
Strategic sewers are the most important in our wastewater network and we’re unlikely to consent to building over them.
Rising mains
You can’t build over a pressurised sewer (which pumps foul sewage or rainwater). The alternative is to divert the sewer and upgrade the pump, which requires extensive construction works. Learn more about diverting a sewer.
Can I divert a sewer?
There are two ways to apply for a sewer diversion, depending on the complexity of your requirements.
Build over: minor sewer diversions
For short diversions to smaller sewers required for domestic extensions or home improvements, you may be able to apply for a minor diversion. Your proposal must meet the following criteria:
- The internal diameter of the sewer to be diverted is 150mm or less
- The total length of the sewer diversion is 20m or less
A CCTV survey will be required before construction begins, to assess the condition of the sewer, and after it’s been completed, to ensure it’s been constructed to the agreed specifications and no damage has occurred. A refundable cash deposit of £2,000 is required and will be refunded once the completed diversion has been inspected by Thames Water and found to be in a satisfactory condition.
To apply for a minor sewer diversion, complete the build over application online.
Sewer diversions
If you do not meet the minor sewer diversion, you’ll need to complete a full sewer diversion application.
Read more about the process and complete an application.
How much does a build over agreement cost?
Current build over application costs:
- Class 1: £130 - the internal diameter of the sewer is 175mm or less
- Class 2: £490 - the internal diameter of the sewer is 176mm to 350mm
- Class 3: £585 - the internal diameter of the sewer is over 350mm, plus additional legal costs starting at £1,000
These charges are updated on 1 April each year.